Product Details:
Capacity | 2.5 m3 / h |
Installation Position | Horizontal / Vertical |
Intel Pressure Range | 26mbar (g) - 300mbar (g) |
Outlet Pressure Range | 18 - 30 mbar |
Operating Temperature | 20 to 60 Deg C |
Inlet X Outlet | 1/2" NPT (FLN) X 3/4" NPT (FLN) |
Casing | Pressure Die Casted Aluminium Alloy |
Elastomers | Nitrile Rubber (Buna - N) |
Internals | Aluminum,Brass,Derylin & Stainless Steel |
Suitable For | Natural Gas & LPG |
Filter | In-built |
Type of Reset | UPSO Auto Reset / Manual |
Connection Orientation | Inlet & Outlet Connection at 90 Degree/ in line |
A Gas Pressure Regulator commonly known as “Meter Regulator”, is mainly used for household /residential/domestic purpose. The Regulator is suitable for both natural gas as well as LPG. The main purpose of the regulator is to supply gas at constant set outlet pressure. Raychem RPG regulator meets the current standards. It uses well-proven principles of control dynamics together with modern assembly techniques to produce a regulator that offers excellent performance in a compact, low cost, and maintenance free unit.
Applications:
Product Details:
Flow Range | 6 - 10 - 15 - 25 - 30 - 50 - 60 m 3 / h |
Inlet Connection | 1/2",3/4",1 ISO 228/1 BSPP - ISO 228/1 BSPT - ANSI / ASME B 1.20.1 NPT Threaded |
Output Connection | Output 1",11/4",11/2",2" ISO 228/1 BSPP - ISO 228/1 BSPT - ANSI / ASME B 1.20.1 NPT |
Inlet Pressure Range | 0.5 bar to 6 bar |
Output Pressure Range | 16 mbar to 350 mbar |
Filter | Bronze |
Pressure class | PN4 and PN6 |
Number of Tiers | Double Stage |
Accuracy Class | Output Tolerance AC 10 (+/- 10%) (AC5 on request) |
Shutdown Tolerance | SG20 (+ 20%) |
Operating Temperature Range | -20 to 60 Deg C (-40 Deg C on request) |
Angle Between Input and Output | 90 Degree or U Type |
Discharge Pressure | Adjustable on request |
Evacuation Safety Tolerance | +/- 10% |
Overcurrent Flow | 120 to 150% of the maximum flow rate (adjustable on request) |
Excess Flow Tolerance | +/- 10% |
Structural Supplementary Features | Closing in output pressure reduction,evacuation in outlet pressure |
Material Standards | Aluminum - EN 1706,Brass - EN 12164,Rubbers - EN 549 |
Materials | Body and cover EN AC-46100 Aluminum,Plastic materials Nylon and Pom,Rubber materials NBR |
ERG-S series gas pressure regulators are used in gas lines. Output pressure range can be adjusted with different spring selection. ERG-S series are used in dual-connection (conical spherical connection), two-stage, PN4 and PN6 rated pressure, gas pressure regulators, underground and above service boxes, equipped with discharge safety valve. It is a safe, high performance, long life gas armature that can reduce the various gas inlet pressure up to the permissible rated pressure at the output side and keep it constant within certain tolerances.
Product Details:
Flow Range | 6 - 10 - 15 - 25 - 30 - 50 - 60 m 3 / h |
Inlet Connection | 1/2",3/4",1 ISO 228/1 BSPP - ISO 228/1 BSPT - ANSI / ASME B 1.20.1 NPT Threaded |
Output Connection | Output 1",11/4",11/2",2" ISO 228/1 BSPP - ISO 228/1 BSPT - ANSI / ASME B 1.20.1 NPT |
Inlet Pressure Range | 0.5 bar to 6 bar |
Output Pressure Range | 16 mbar to 350 mbar |
Number of Tiers | Double Stage |
Accuracy Class | Output Tolerance AC 10 (+/- 10%) (AC5 on request) |
Shutdown Tolerance | SG20 (+ 20%) |
Operating Temperature Range | -20 to 60 Deg C (-40 Deg C on request) |
Angle Between Input and Output | 90 Degree or U Type |
Discharge Pressure | Adjustable on request |
Evacuation Safety Tolerance | +/- 10% |
Maximum safety closing pressure range | Adjustable on request |
Maximum Safety Shutdown Tolerance | 20% |
Overcurrent Flow | 120 to 150% of the maximum flow rate (adjustable on request) |
Excess Flow Tolerance | +/- 10% |
Material Standards | Aluminum - EN 1706,Brass - EN 12164,Rubbers - EN 549 |
Materials | Body and cover EN AC-46100 Aluminum,Plastic materials Nylon and Pom,Rubber materials NBR |
Safety Shutdown Time | Under 1 second |
Pressure class | PN4 and PN6 |
ERG-SE series gas pressure regulators are used in gas lines. Output pressure range can be adjusted with different spring selection. ERG-SE series are used in dual-connection (conical spherical connection), two-stage, PN4 and PN6 rated pressure, gas pressure regulators, underground and above service boxes, equipped with drain safety valve and closing safety valve. It is a safe, high performance, long life gas armature that can reduce the various gas inlet pressure up to the permissible rated pressure at the output side and keep it constant within certain tolerances.
Features:
Product Details:
Maximum Inlet Pressure | 6 bar |
Body Material | Aluminum comply with EN 1706 standard |
Assembly | Vertical and Horizontal Position |
Outlet pressure range | 15 to 360 mbar |
Refering | Ped 2014/68/EU |
Medium | Natural Gas,LPG and Non-Corrosive Gases |
Operating temperature | -20 to +60 Deg C (optional -40 to +60 Deg C) |
Filter | Included |
ERG-SR Series pressure regulator is used on gas line to reduce inlet pressure to desired outlet pressure. It is suitable for both commercial and residential usage where can be directly installed to gas meters with high operational reliability and accurate outlet pressure accuracy. Simple installation procedure. Direction of the line can be inline or angle. Due to different inlet and outlet connection range, ERG-SR Series can be used along with pipe diameter from DN20 to DN50 with different thread standards as well as BSP, BSPT, NPT, NPP. (Also, can be added to flange connection.), The regulators are manufactured according to Ped Directive 2014/68/EU. The functional tests are performed according to EN334.
Features:
Design:
Product Details:
Flow Range | 6 - 10 - 15 - 25 - 30 - 50 - 60 m 3 / h |
Pressure class | PN4 and PN6 |
Inlet Connection | 1/2 ", 3/4", 1 "Thread |
Outlet Connection | 1 ", 11/4", 11/2 ", 2" Thread |
Inlet Pressure Range | 0.5 bar to 6 bar |
Output Pressure Range | 16 mbar to 350 mbar |
Structural Supplementary Features | Closing in output pressure reduction, evacuation in outlet pressure |
Uses | Underground and above ground service boxes in gas networks and gas pipelines in city and industrial |
Fluid | Natural gas, LPG, Propane, Butane, City gas, Air-like non-corrosive gases |
ERG-S Double Stage gas pressure regulators are used in gas lines to reduce the maximum 6 bar inlet pressure to the desired output pressure between 16 and 350 mbar. Output pressure range can be adjusted with different spring selection
ERG-S Double Stage gas pressure regulator are used in dual-connection (conical spherical connection), two-stage, PN4 and PN6 rated pressure, gas pressure regulators, underground and above service boxes, equipped with discharge safety valve. It is a safe, high performance, long life gas armature that can reduce the various gas inlet pressure up to the permissible rated pressure at the output side and keep it constant within certain tolerances.
Product Details:
Max inlet pressure | 1 to 20 bar |
Max outlet pressure | MPO 100 to 800 and HPO 800 to 4 bar |
Operating temperature | -20 to +60 Deg C (optional -40 to +60 Deg C) |
Assembly | Vertical and Horizontal Position |
Outlet pressure range | 100 mbar to 4 bar |
Body Material | Aluminum,Steel or Iron |
ERG-H1 Series pressure regulator is used on gasline to reduce inlet pressure to desired outlet pressure. ERG-H1 series pressure regulators are suitable for commercial. It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H1 is a single stage regulator with an optional security systems such as relief valve, UPSO and OPSO. The regulators are manufactured according to Ped Directive 2014/68/EU.
Features:
Design:
Product Details:
Assembly | Vertical and Horizontal Position |
Conforming | 2014/68/EU |
Filter | As a standard 100 micron pore diameter. |
Maximum inlet pressure | 6 bar (Optional 10 bar,20 bar) |
Medium | Natural Gas,LPG and Non-Corrosive Gases |
Operating temperature | -20 to +60 Deg C (optional -40 to +60 Deg C) |
Outlet pressure range | 15 mbar to 2,5 bar |
ERG-H5 Series pressure regulator which is used on gas line to reduce inlet pressure to desired outlet pressure.ERG-H5 series pressure regulators are suitable for commercial, It is mainly used in Distribution of Natural Gas and also suitable to use with non-corrosive gases. ERG-H5 is a single stage direct acting regulator with a optional security systems such as relief valve UPSO and OPSO.
Features:
Design:
Product Details:
Flow Range | 15 - 120 m 3 / h |
Pressure Class | PN1 |
Outlet Pressure Range | 16 mbar to 150 mbar |
Connection | 1/2 2,3/4 11,1 /4,11/4 1,11/2 3,2 thread |
Input Pressure Range | 50 mbar to 1 bar |
Filter | 50 micron (10-20 micron on request) |
Number of Tiers | Single Stage |
Accuracy Class Output Tolerance | AC 10 (+- 10%) |
Shutdown Tolerance | SG30 (+ 30%) |
Operating Temperature Range | -20 to 60 Deg C (-40 Deg C on request) |
Maximum Safety Shutdown Pressure Range | 30 mbar to 200 mbar |
Minimum Safety Shutdown Pressure Range | 12 mbar to 40 mbar |
Minimum Safety Shutdown Tolerance | 20% |
Shutdown Time | Under 1 second |
Standards Material | Aluminum - EN 1706,Brass - EN 12164,Rubbers - EN 549 |
Body Material | EN AC-46100 Aluminum,Plastic materials Nylon,Rubber materials NBR,filter bracket metal |
ERG-E series gas pressure regulators are used in gas lines to reduce the maximum inlet pressure. The output pressure range can be adjusted with different spring selection. Safety shut-off regulator is automatically activated to ensure the safety of the devices used in the system and cuts the gas flow in the line if the output pressure exceeds or exceeds the set value thanks to the safety closing system it contains. ERG-E series safety shut-off gas pressure regulators, which can be used in industrial and urban networks, can be used in industrial and urban networks to allow various different gas inlet pressure to decrease to the desired value on the output side due to manual spring adjustment. Thanks to the washable filter cartridge, gas-borne dust is a gas armature that can filter out dirt-like particles. In our ERG-E series regulators, there is a safety closing device to prevent the surge and / or fall in the output pressure and these regulators are regulators which can automatically cut the gas supply in case of unwanted pressure changes in the outlet pressure by means of the safety closing device.